2. Professional system
3. Good quality
4. Fast delivery
ACSR conductor widely used in power transmission lines with various voltage levels.
AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels. Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power
Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Construction
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.
Specifications
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Code name |
Nominal aluminum area mm 2 | Stranding structure | Total sectional area | Overall diameter | |||
Al. No. | Al. Dia. | St. No. | St. Dia | mm 2 | mm |
Jaguar | 200 | 18 | 3.86 | 1 | 3.86 | 222.30 | 19.30 |
Panther | 200 | 30 | 3.00 | 7 | 3.00 | 261.50 | 21.00 |
Lion | 225 | 30 | 3.18 | 7 | 3.18 | 294.20 | 22.26 |
Bear | 250 | 30 | 3.35 | 7 | 3.35 | 325.60 | 23.45 |
Goat | 300 | 30 | 3.71 | 7 | 3.71 | 400.00 | 25.97 |
Sheep | 350 | 30 | 3.99 | 7 | 3.99 | 461.40 | 27.93 |
Antilope | 350 | 54 | 2.97 | 7 | 2.97 | 421.50 | 26.73 |
Bizon | 350 | 54 | 3.00 | 7 | 3.00 | 431.30 | 27.00 |
Deer | 400 | 30 | 4.27 | 7 | 4.27 | 529.50 | 28.89 |
Zebra | 400 | 54 | 3.18 | 7 | 3.18 | 484.50 | 28.62 |
ELK | 450 | 30 | 4.50 | 7 | 4.50 | 588.30 | 31.50 |
Camel | 450 | 54 | 3.35 | 7 | 3.35 | 536.80 | 30.15 |
Moose | 500 | 54 | 3.53 | 7 | 3.53 | 597.20 | 31.77 |
Finch | 500 | 54 | 3.65 | 19 | 2.29 | 642.90 | 33.35 |
Product Description
Â
 Steel cored aluminum SCA conductor ACSR conductor
Â
 Standard: ASTM B232 ,IEC61089, BS215 part2, DIN48204, BS EN50182, GB/T 1179-2008Â
Â
 Brief Description:
Â
ACSR conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C. GRADE).
ACSR Conductor may be manufactured for having a wide range of tensile strength as per requirement.Â
The principal advantage of these conductors are high tensile strength and light weight with longer spans as well as with lesser supports. Due to the greater diameter of ACS Conductor a much higher corona limit can be obtained causing  big advantages on high as well as extra high voltage overhead lines.
Â
 Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable.Â
ACSR Conductor   offers optimal strength for line design. Variable steel core stranding enablesÂ
desired strength to be achieved without sacrificing ampacity. ACSR Conductor  are used extensively
 for overhead ground wires, river crossings etc. These ACSR Conductor  are available with us in various types for  meeting the exact requirements of the clients.Â
Â
CONSTRUCTION
Â
• Aluminum 1350H19 wires, concentrically stranded about a steel core. Standard core wire for ACSR is class A galvanized.
• Class A core stranding is also available in zinc-5% aluminum-mischmetal alloy coating.
• For aluminum-clad (AW) ACSR, please refer to the ACSR/AW catalog sheet
• Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease.
• ACSR conductor is also available in non-specular
We could producing according to the customers' requirements.Welcome your request for any quotations
Â
Â
Aluminum Conductors Steel Reinforced         ASTM B 232 | ||||||||
Code name | Area | Stranding and wire diameter | Approx. overall diameter | Â | Nominal breaking load | Nominal DC resistance at 20 deg. | ||
Nominal | Total | Alum. | Steel | Total | ||||
 | AWG or MCM | mm2 | mm | mm | mm | kg/km | kN | Ohm/km |
TURKEY | 6 | 15.48 | 6/1.68 | 1/1.68 | 5.04 | 54 | 5.24 | 2.1586 |
SWAN | 4 | 24.71 | 6/2.12 | 1/2.12 | 6.36 | 85 | 8.32 | 1.3557 |
SWANATE | 4 | 26.51 | 7/1.96 | 1/2.61 | 6.53 | 100 | 10.53 | 1.3557 |
SPARROW | 2 | 39.22 | 6/2.67 | 1/2.67 | 8.01 | 136 | 12.7 | 0.8535 |
SPARATE | 2 | 42.13 | 7/2.47 | 1/3.30 | 8.24 | 159 | 16.11 | 0.8535 |
RAVEN | 1/0 | 62.38 | 6/3.37 | 1/3.37 | 10.11 | 216 | 19.32 | 0.5364 |
QUAIL | 2/0 | 78.65 | 6/3.78 | 1/3.78 | 11.34 | 273 | 23.62 | 0.4255 |
PIGEON | 3/0 | 99.22 | 6/4.25 | 1/4.25 | 12.75 | 343 | 29.41 | 0.3373 |
PENGUIN | 4/0 | 125.1 | 6/4.77 | 1/4.77 | 14.31 | 433 | 37.06 | 0.2675 |
PARTRIDGE | 266.8 | 157.16 | 26/2.57 | 7/2.00 | 16.28 | 546 | 50.29 | 0.2143 |
MERLIN | 336.4 | 179.93 | 18/3.47 | 1/3.47 | 17.35 | 544 | 38.23 | 0.1691 |
LINNET | 336.4 | 198.26 | 26/2.89 | 7/2.25 | 18.31 | 689 | 62.71 | 0.1699 |
ORIOLE | 336.4 | 210.26 | 30/2.69 | 7/2.69 | 18.83 | 784 | 77.27 | 0.1704 |
IBIS | 397.5 | 234.19 | 26/3.14 | 7/2.44 | 19.88 | 814 | 72.11 | 0.1438 |
LARK | 397.5 | 248.39 | 30/2.92 | 7/2.92 | 20.44 | 927 | 88.69 | 0.1442 |
PELICAN | 477 | 255.1 | 18/4.14 | 1/4.14 | 20.7 | 771 | 52.16 | 0.1193 |
FLICKER | 477 | 272.97 | 24/3.58 | 7/2.39 | 21.49 | 915 | 76.66 | 0.1199 |
HAWK | 477 | 281.1 | 26/3.44 | 7/2.67 | 21.79 | 978 | 86.65 | 0.1199 |
HEN | 477 | 298.07 | 30/3.20 | 7/3.20 | 22.4 | 1112 | 105.34 | 0.1201 |
OSPREY | 556.5 | 297.68 | 18/4.47 | 1/4.47 | 22.35 | 899 | 60.88 | 0.1022 |
PARAKEET | 556.5 | 318.58 | 24/3.87 | 7/2.58 | 23.22 | 1067 | 88.22 | 0.1027 |
DOVE | 556.5 | 327.94 | 26/3.72 | 7/2.89 | 23.55 | 1140 | 101.03 | 0.1027 |
EAGLE | 556.5 | 347.81 | 30/3.46 | 7/3.46 | 24.21 | 1298 | 122.92 | 0.103 |
PEACOCK | 605 | 346.32 | 24/4.03 | 7/2.69 | 24.2 | 1160 | 95.88 | 0.0945 |
SQUAB | 605 | 356.52 | 26/3.87 | 7/3.01 | 24.51 | 1240 | 108.14 | 0.0945 |
TEAL | 605 | 376.45 | 30/3.61 | 19/2.16 | 25.24 | 1399 | 133.59 | 0.0947 |
GROSBEAK | 636 | 374.71 | 26/3.97 | 7/3.09 | 25.15 | 1302 | 111.8 | 0.08989 |
STARLING | 715.5 | 421.61 | 26/4.21 | 7/3.28 | 26.68 | 1466 | 125.91 | 0.07989 |
TERN | 795 | 430.71 | 45/3.38 | 7/2.25 | 27.03 | 1333 | 97.37 | 0.07191 |
CONDOR | 795 | 455.03 | 54/3.08 | 7/3.08 | 27.72 | 1524 | 124.45 | 0.07191 |
CUCKOO | 795 | 455.03 | 24/4.62 | 7/3.08 | 27.74 | 1524 | 123.94 | 0.07191 |
DRAKE | 795 | 468.35 | 26/4.44 | 7/3.45 | 28.11 | 1628 | 139.92 | 0.07191 |
MALLARD | 795 | 494.71 | 30/4.14 | 19/2.48 | 28.96 | 1838 | 171.18 | 0.07208 |
RAIL | 954 | 516.84 | 45/3.70 | 7/2.47 | 29.61 | 1601 | 115.63 | 0.05992 |
CURLEW | 1033.5 | 591.55 | 54/3.52 | 7/3.52 | 31.68 | 1981 | 161.8 | 0.05531 |
BLUEJAY | 1113 | 602.96 | 45/4.00 | 7/2.66 | 31.98 | 1868 | 132.63 | 0.05136 |
FINCH | 1113 | 635.48 | 54/3.65 | 19/2.19 | 32.85 | 2150 | 174.41 | 0.05161 |
GRACKLE | 1192.5 | 680.84 | 54/3.77 | 19/2.27 | 33.97 | 2282 | 186.38 | 0.04817 |
BITTERN | 1272 | 689.03 | 45/4.27 | 7/2.85 | 34.17 | 2134 | 151.48 | 0.04494 |
DIPPER | 1351.5 | 731.94 | 45/4.40 | 7/2.92 | 35.16 | 2266 | 160.7 | 0.0423 |
MARTIN | 1351.5 | 771.55 | 54/4.02 | 19/2.41 | 36.17 | 2585 | 206.05 | 0.0425 |
LAPWING | 1590 | 861.16 | 45/4.77 | 7/3.18 | 38.16 | 2667 | 187.02 | 0.03595 |
FALCON | 1590 | 907.81 | 54/4.36 | 19/2.62 | 39.26 | 3042 | 242.55 | 0.03613 |
DOTTEREL | 176.9 | 141.67 | 12/3.08 | 7/3.08 | 15.42 | 657 | 78.5 | 0.3237 |
DORKING | 190.8 | 153.1 | 12/3.20 | 7/3.20 | 16.03 | 709 | 84.8 | 0.2995 |
COCHIN | 211.8 | 169.55 | 12/3.37 | 7/3.37 | 16.84 | 785 | 93.9 | 0.2705 |
Aluminum Conductors Steel Reinforced           BS 215 Part 2 | ||||||||
Code name | Area | Stranding and wire diameter | Approx. overall diameter | Â | Nominal breaking load | Nominal DC resistance at 20 deg. | ||
Nominal | Total | Alum. | Steel | Total | ||||
 | mm2 | mm2 | mm | mm | mm | kg/km | kN | Ohm/km |
MOLE | 10 | 12.39 | 6/1.50 | 1/1.50 | 4.5 | 43 | 4.14 | 2.076 |
SQUIRREL | 20 | 24.43 | 6/2.11 | 1/2.11 | 6.33 | 85 | 7.88 | 1.368 |
GOPHER | 25 | 30.62 | 6/2.36 | 1/2.36 | 7.08 | 106 | 9.61 | 1.093 |
WEASEL | 30 | 36.88 | 6/2.59 | 1/2.59 | 7.77 | 128 | 11.45 | 0.9077 |
FOX | 35 | 42.77 | 6/2.79 | 1/2.79 | 8.37 | 149 | 13.2 | 0.7822 |
FERRET | 40 | 49.48 | 6/3.00 | 1/3.00 | 9 | 172 | 15.2 | 0.6766 |
RABBIT | 50 | 61.7 | 6/3.35 | 1/3.35 | 10.05 | 214 | 18.35 | 0.5426 |
HORSE | 70 | 116.17 | 12/2.79 | 7/2.79 | 13.95 | 538 | 61.2 | 0.3936 |
RACOON | 75 | 92.4 | 6/4.10 | 1/4.10 | 12.3 | 320 | 27.2 | 0.3622 |
OTTER | 80 | 97.86 | 6/4.22 | 1/4.22 | 12.66 | 339 | 28.8 | 0.3419 |
CAT | 90 | 111.3 | 6/4.50 | 1/4.50 | 13.5 | 386 | 32.7 | 0.3007 |
HARE | 100 | 122.5 | 6/4.72 | 1/4.72 | 14.16 | 425 | 36 | 0.2733 |
DOG | 100 | 118.5 | 6/4.72 | 7/1.57 | 14.15 | 394 | 32.7 | 0.2733 |
TIGER | 125 | 161.7 | 30/2.36 | 7/2.36 | 16.52 | 602 | 58 | 0.2202 |
WOLF | 150 | 194.9 | 30/2.59 | 7/2.59 | 18.13 | 726 | 69.2 | 0.1828 |
LYNX | 175 | 226.2 | 30/2.79 | 7/2.79 | 19.53 | 842 | 79.8 | 0.1576 |
CARACAL | 175 | 194.5 | 18/3.61 | 1/3.61 | 18.05 | 587 | 41.1 | 0.1563 |
PANTHER | 200 | 261.5 | 30/3.00 | 7/3.00 | 21 | 974 | 92.25 | 0.1363 |
BEAR | 250 | 325.6 | 30/3.35 | 7/3.35 | 23.45 | 1213 | 111.1 | 0.1093 |
BISON | 350 | 431.3 | 54/3.00 | 7/3.00 | 27 | 1444 | 120.9 | 0.07573 |
DEER | 400 | 529.5 | 30/4.27 | 7/4.27 | 29.89 | 1971 | 178.5 | 0.06726 |
ZEBRA | 400 | 484.5 | 54/3.18 | 7/3.18 | 28.62 | 1621 | 131.9 | 0.0674 |
MOOSE | 500 | 597.2 | 54/3.53 | 7/3.53 | 31.77 | 1999 | 161.1 | 0.0547 |
Â
Â
Steel cored aluminum SCA conductor ACSR Aluminum Conductor Steel-reinforced Power Cable
Â
 Features:
 1) It is manufactured according to ASTM B232 ,IEC61089, BS215 part2, DIN48204, BS EN50182, GB/T 1179-2008Â
2) rated voltage is 500KV or lower
3) This series includes:
a) All aluminum conductors (AAC)
b) All aluminum alloy conductors (AAAC)
c) Aluminum conductor steel reinforced (ACSR)
d) Anti-corrosion ACSR
e) All steel conductors
4)Packing:Standard export wooden drums
1. CCC certification2. Professional system
3. Good quality
4. Fast delivery
ACSR conductor widely used in power transmission lines with various voltage levels.
AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels. Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power
Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Construction
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.
Specifications
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Code name |
Nominal aluminum area mm 2 | Stranding structure | Total sectional area | Overall diameter | |||
Al. No. | Al. Dia. | St. No. | St. Dia | mm 2 | mm |
Jaguar | 200 | 18 | 3.86 | 1 | 3.86 | 222.30 | 19.30 |
Panther | 200 | 30 | 3.00 | 7 | 3.00 | 261.50 | 21.00 |
Lion | 225 | 30 | 3.18 | 7 | 3.18 | 294.20 | 22.26 |
Bear | 250 | 30 | 3.35 | 7 | 3.35 | 325.60 | 23.45 |
Goat | 300 | 30 | 3.71 | 7 | 3.71 | 400.00 | 25.97 |
Sheep | 350 | 30 | 3.99 | 7 | 3.99 | 461.40 | 27.93 |
Antilope | 350 | 54 | 2.97 | 7 | 2.97 | 421.50 | 26.73 |
Bizon | 350 | 54 | 3.00 | 7 | 3.00 | 431.30 | 27.00 |
Deer | 400 | 30 | 4.27 | 7 | 4.27 | 529.50 | 28.89 |
Zebra | 400 | 54 | 3.18 | 7 | 3.18 | 484.50 | 28.62 |
ELK | 450 | 30 | 4.50 | 7 | 4.50 | 588.30 | 31.50 |
Camel | 450 | 54 | 3.35 | 7 | 3.35 | 536.80 | 30.15 |
Moose | 500 | 54 | 3.53 | 7 | 3.53 | 597.20 | 31.77 |
Finch | 500 | 54 | 3.65 | 19 | 2.29 | 642.90 | 33.35 |
Product Description
Â
 Steel cored aluminum SCA conductor ACSR conductor
Â
 Standard: ASTM B232 ,IEC61089, BS215 part2, DIN48204, BS EN50182, GB/T 1179-2008Â
Â
 Brief Description:
Â
ACSR conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C. GRADE).
ACSR Conductor may be manufactured for having a wide range of tensile strength as per requirement.Â
The principal advantage of these conductors are high tensile strength and light weight with longer spans as well as with lesser supports. Due to the greater diameter of ACS Conductor a much higher corona limit can be obtained causing  big advantages on high as well as extra high voltage overhead lines.
Â
 Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable.Â
ACSR Conductor   offers optimal strength for line design. Variable steel core stranding enablesÂ
desired strength to be achieved without sacrificing ampacity. ACSR Conductor  are used extensively
 for overhead ground wires, river crossings etc. These ACSR Conductor  are available with us in various types for  meeting the exact requirements of the clients.Â
Â
CONSTRUCTION
Â
• Aluminum 1350H19 wires, concentrically stranded about a steel core. Standard core wire for ACSR is class A galvanized.
• Class A core stranding is also available in zinc-5% aluminum-mischmetal alloy coating.
• For aluminum-clad (AW) ACSR, please refer to the ACSR/AW catalog sheet
• Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease.
• ACSR conductor is also available in non-specular
We could producing according to the customers' requirements.Welcome your request for any quotations
Â
Â
Aluminum Conductors Steel Reinforced         ASTM B 232 | ||||||||
Code name | Area | Stranding and wire diameter | Approx. overall diameter | Â | Nominal breaking load | Nominal DC resistance at 20 deg. | ||
Nominal | Total | Alum. | Steel | Total | ||||
 | AWG or MCM | mm2 | mm | mm | mm | kg/km | kN | Ohm/km |
TURKEY | 6 | 15.48 | 6/1.68 | 1/1.68 | 5.04 | 54 | 5.24 | 2.1586 |
SWAN | 4 | 24.71 | 6/2.12 | 1/2.12 | 6.36 | 85 | 8.32 | 1.3557 |
SWANATE | 4 | 26.51 | 7/1.96 | 1/2.61 | 6.53 | 100 | 10.53 | 1.3557 |
SPARROW | 2 | 39.22 | 6/2.67 | 1/2.67 | 8.01 | 136 | 12.7 | 0.8535 |
SPARATE | 2 | 42.13 | 7/2.47 | 1/3.30 | 8.24 | 159 | 16.11 | 0.8535 |
RAVEN | 1/0 | 62.38 | 6/3.37 | 1/3.37 | 10.11 | 216 | 19.32 | 0.5364 |
QUAIL | 2/0 | 78.65 | 6/3.78 | 1/3.78 | 11.34 | 273 | 23.62 | 0.4255 |
PIGEON | 3/0 | 99.22 | 6/4.25 | 1/4.25 | 12.75 | 343 | 29.41 | 0.3373 |
PENGUIN | 4/0 | 125.1 | 6/4.77 | 1/4.77 | 14.31 | 433 | 37.06 | 0.2675 |
PARTRIDGE | 266.8 | 157.16 | 26/2.57 | 7/2.00 | 16.28 | 546 | 50.29 | 0.2143 |
MERLIN | 336.4 | 179.93 | 18/3.47 | 1/3.47 | 17.35 | 544 | 38.23 | 0.1691 |
LINNET | 336.4 | 198.26 | 26/2.89 | 7/2.25 | 18.31 | 689 | 62.71 | 0.1699 |
ORIOLE | 336.4 | 210.26 | 30/2.69 | 7/2.69 | 18.83 | 784 | 77.27 | 0.1704 |
IBIS | 397.5 | 234.19 | 26/3.14 | 7/2.44 | 19.88 | 814 | 72.11 | 0.1438 |
LARK | 397.5 | 248.39 | 30/2.92 | 7/2.92 | 20.44 | 927 | 88.69 | 0.1442 |
PELICAN | 477 | 255.1 | 18/4.14 | 1/4.14 | 20.7 | 771 | 52.16 | 0.1193 |
FLICKER | 477 | 272.97 | 24/3.58 | 7/2.39 | 21.49 | 915 | 76.66 | 0.1199 |
HAWK | 477 | 281.1 | 26/3.44 | 7/2.67 | 21.79 | 978 | 86.65 | 0.1199 |
HEN | 477 | 298.07 | 30/3.20 | 7/3.20 | 22.4 | 1112 | 105.34 | 0.1201 |
OSPREY | 556.5 | 297.68 | 18/4.47 | 1/4.47 | 22.35 | 899 | 60.88 | 0.1022 |
PARAKEET | 556.5 | 318.58 | 24/3.87 | 7/2.58 | 23.22 | 1067 | 88.22 | 0.1027 |
DOVE | 556.5 | 327.94 | 26/3.72 | 7/2.89 | 23.55 | 1140 | 101.03 | 0.1027 |
EAGLE | 556.5 | 347.81 | 30/3.46 | 7/3.46 | 24.21 | 1298 | 122.92 | 0.103 |
PEACOCK | 605 | 346.32 | 24/4.03 | 7/2.69 | 24.2 | 1160 | 95.88 | 0.0945 |
SQUAB | 605 | 356.52 | 26/3.87 | 7/3.01 | 24.51 | 1240 | 108.14 | 0.0945 |
TEAL | 605 | 376.45 | 30/3.61 | 19/2.16 | 25.24 | 1399 | 133.59 | 0.0947 |
GROSBEAK | 636 | 374.71 | 26/3.97 | 7/3.09 | 25.15 | 1302 | 111.8 | 0.08989 |
STARLING | 715.5 | 421.61 | 26/4.21 | 7/3.28 | 26.68 | 1466 | 125.91 | 0.07989 |
TERN | 795 | 430.71 | 45/3.38 | 7/2.25 | 27.03 | 1333 | 97.37 | 0.07191 |
CONDOR | 795 | 455.03 | 54/3.08 | 7/3.08 | 27.72 | 1524 | 124.45 | 0.07191 |
CUCKOO | 795 | 455.03 | 24/4.62 | 7/3.08 | 27.74 | 1524 | 123.94 | 0.07191 |
DRAKE | 795 | 468.35 | 26/4.44 | 7/3.45 | 28.11 | 1628 | 139.92 | 0.07191 |
MALLARD | 795 | 494.71 | 30/4.14 | 19/2.48 | 28.96 | 1838 | 171.18 | 0.07208 |
RAIL | 954 | 516.84 | 45/3.70 | 7/2.47 | 29.61 | 1601 | 115.63 | 0.05992 |
CURLEW | 1033.5 | 591.55 | 54/3.52 | 7/3.52 | 31.68 | 1981 | 161.8 | 0.05531 |
BLUEJAY | 1113 | 602.96 | 45/4.00 | 7/2.66 | 31.98 | 1868 | 132.63 | 0.05136 |
FINCH | 1113 | 635.48 | 54/3.65 | 19/2.19 | 32.85 | 2150 | 174.41 | 0.05161 |
GRACKLE | 1192.5 | 680.84 | 54/3.77 | 19/2.27 | 33.97 | 2282 | 186.38 | 0.04817 |
BITTERN | 1272 | 689.03 | 45/4.27 | 7/2.85 | 34.17 | 2134 | 151.48 | 0.04494 |
DIPPER | 1351.5 | 731.94 | 45/4.40 | 7/2.92 | 35.16 | 2266 | 160.7 | 0.0423 |
MARTIN | 1351.5 | 771.55 | 54/4.02 | 19/2.41 | 36.17 | 2585 | 206.05 | 0.0425 |
LAPWING | 1590 | 861.16 | 45/4.77 | 7/3.18 | 38.16 | 2667 | 187.02 | 0.03595 |
FALCON | 1590 | 907.81 | 54/4.36 | 19/2.62 | 39.26 | 3042 | 242.55 | 0.03613 |
DOTTEREL | 176.9 | 141.67 | 12/3.08 | 7/3.08 | 15.42 | 657 | 78.5 | 0.3237 |
DORKING | 190.8 | 153.1 | 12/3.20 | 7/3.20 | 16.03 | 709 | 84.8 | 0.2995 |
COCHIN | 211.8 | 169.55 | 12/3.37 | 7/3.37 | 16.84 | 785 | 93.9 | 0.2705 |
Aluminum Conductors Steel Reinforced           BS 215 Part 2 | ||||||||
Code name | Area | Stranding and wire diameter | Approx. overall diameter | Â | Nominal breaking load | Nominal DC resistance at 20 deg. | ||
Nominal | Total | Alum. | Steel | Total | ||||
 | mm2 | mm2 | mm | mm | mm | kg/km | kN | Ohm/km |
MOLE | 10 | 12.39 | 6/1.50 | 1/1.50 | 4.5 | 43 | 4.14 | 2.076 |
SQUIRREL | 20 | 24.43 | 6/2.11 | 1/2.11 | 6.33 | 85 | 7.88 | 1.368 |
GOPHER | 25 | 30.62 | 6/2.36 | 1/2.36 | 7.08 | 106 | 9.61 | 1.093 |
WEASEL | 30 | 36.88 | 6/2.59 | 1/2.59 | 7.77 | 128 | 11.45 | 0.9077 |
FOX | 35 | 42.77 | 6/2.79 | 1/2.79 | 8.37 | 149 | 13.2 | 0.7822 |
FERRET | 40 | 49.48 | 6/3.00 | 1/3.00 | 9 | 172 | 15.2 | 0.6766 |
RABBIT | 50 | 61.7 | 6/3.35 | 1/3.35 | 10.05 | 214 | 18.35 | 0.5426 |
HORSE | 70 | 116.17 | 12/2.79 | 7/2.79 | 13.95 | 538 | 61.2 | 0.3936 |
RACOON | 75 | 92.4 | 6/4.10 | 1/4.10 | 12.3 | 320 | 27.2 | 0.3622 |
OTTER | 80 | 97.86 | 6/4.22 | 1/4.22 | 12.66 | 339 | 28.8 | 0.3419 |
CAT | 90 | 111.3 | 6/4.50 | 1/4.50 | 13.5 | 386 | 32.7 | 0.3007 |
HARE | 100 | 122.5 | 6/4.72 | 1/4.72 | 14.16 | 425 | 36 | 0.2733 |
DOG | 100 | 118.5 | 6/4.72 | 7/1.57 | 14.15 | 394 | 32.7 | 0.2733 |
TIGER | 125 | 161.7 | 30/2.36 | 7/2.36 | 16.52 | 602 | 58 | 0.2202 |
WOLF | 150 | 194.9 | 30/2.59 | 7/2.59 | 18.13 | 726 | 69.2 | 0.1828 |
LYNX | 175 | 226.2 | 30/2.79 | 7/2.79 | 19.53 | 842 | 79.8 | 0.1576 |
CARACAL | 175 | 194.5 | 18/3.61 | 1/3.61 | 18.05 | 587 | 41.1 | 0.1563 |
PANTHER | 200 | 261.5 | 30/3.00 | 7/3.00 | 21 | 974 | 92.25 | 0.1363 |
BEAR | 250 | 325.6 | 30/3.35 | 7/3.35 | 23.45 | 1213 | 111.1 | 0.1093 |
BISON | 350 | 431.3 | 54/3.00 | 7/3.00 | 27 | 1444 | 120.9 | 0.07573 |
DEER | 400 | 529.5 | 30/4.27 | 7/4.27 | 29.89 | 1971 | 178.5 | 0.06726 |
ZEBRA | 400 | 484.5 | 54/3.18 | 7/3.18 | 28.62 | 1621 | 131.9 | 0.0674 |
MOOSE | 500 | 597.2 | 54/3.53 | 7/3.53 | 31.77 | 1999 | 161.1 | 0.0547 |
Â
Â
Steel cored aluminum SCA conductor ACSR Aluminum Conductor Steel-reinforced Power Cable
Â
 Features:
 1) It is manufactured according to ASTM B232 ,IEC61089, BS215 part2, DIN48204, BS EN50182, GB/T 1179-2008Â
2) rated voltage is 500KV or lower
3) This series includes:
a) All aluminum conductors (AAC)
b) All aluminum alloy conductors (AAAC)
c) Aluminum conductor steel reinforced (ACSR)
d) Anti-corrosion ACSR
e) All steel conductors
4)Packing:Standard export wooden drums
Hp Pavilion 15-Cs 15-Cw,Hp 15-Cw Top Cover,Hp 15-Cs Palmrest,Hp Replacement Parts
S-yuan Electronic Technology Limited , https://www.syuanelectronic.com