- Model NO.: JKLYJ
- Conductor Type: Stranded
- Conductor Material: Aluminum
- Insulation Material: XLPE
- Range of Application: Power Transmission
- Brand: Yifang Cable
- Cores Number: 2+1
- Transport Package: Drums, Coils or According to Customers′ Request
- Origin: China
- Type: Insulated
- Application: Overhead
- Sheath Material: Crosslinking
- Material Shape: Round Wire
- Certification: ISO9001, CE, CCC
- Sheath Color: Black
- Trademark: YIFANG
- Specification: 1.5mm2-1000mm2
- HS Code: 8544492100
Product Details:
Insulation Material XLPE
Type Low Voltage
Conductor Material Aluminum
Jacket NON SHEATH
Application Overhead
Place of Origin Henan China
Brand Name YIFANG
Model Number DUPLEX, TRIPLEX, QUADRUPLEX
Service Drop Cable
1. Application of Service Drop Cable:
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
3. Detaild Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.
3.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.
3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.
Â
DUPLEX | |||||||||||||||||
 |  |  | |||||||||||||||
ABC | |||||||||||||||||
 | |||||||||||||||||
 |  |  |  | ABC | |||||||||||||
 |  | ||||||||||||||||
code | Â | (AAAC) | Â | Â | Â | ||||||||||||
word | Â | Â | Â | Â | Â | Â | Â | Â | |||||||||
 | AWG or kcmil |  | kcmil | mm2 |  |  | Ips |  | cmil | mm2 | in |  | mils | mm | |||
Chihuahua | 1*6AWG+1*30.58 | 7 | 30.58 | 15.495 | 1.68 | 5.04 | 1110 | 1 | 26240 | 13.3 | Â | 4.11 | 4.11 | 45 | 1.14 | 6.40 | 11.44 |
Vizsla | 1*6AWG+1*30.58 | 7 | 30.58 | 15.495 | 1.68 | 5.04 | 1110 | 7 | Â | Â | 0.0612 | 1.5545 | 4.66 | 45 | 1.14 | 6.95 | 11.99 |
Harrier | 1*4AWG+1*48.69 | 7 | 48.69 | 24.672 | 2.12 | 6.36 | 1760 | 1 | 41740 | 21.15 | Â | 5.19 | 5.19 | 45 | 1.14 | 7.48 | 13.84 |
Whippet | 1*4AWG+1*48.69 | 7 | 48.69 | 24.672 | 2.12 | 6.36 | 1760 | 7 | Â | Â | 0.0772 | 1.9609 | 5.88 | 45 | 1.14 | 8.17 | 14.53 |
Schnauzer | 1*2AWG+1*77.47 | 7 | 77.47 | 39.255 | 2.67 | 8.02 | 2800 | 7 | Â | Â | 0.0974 | 2.474 | 7.42 | 45 | 1.14 | 9.71 | 17.73 |
Heeler | 1*1/0AWG+1*123.3 | 7 | 123.3 | 62.477 | 3.37 | 10.11 | 4460 | 19 | 105600 | 53.51 |  | 1.89 | 9.47 | 60 | 1.52 | 12.52 | 22.63 |
 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |
Class 2 stranded conductors for single-core and multi-core cables | |||||||||
 |  |  |  |  |  |  |  |  |  |
Nominal crosssectional area | Minimum number of wires in the conductor | Maximum resistance of conductor at 20ºC | |||||||
Circular | Circular compacted | Shaped | Annealed copper conductor | Aluminium or aluminium alloy conductor | |||||
Cu | Â Al | Cu | Â Al | Cu | Â Al | Plain wires | Metal-coated wires | ||
mm2 | Ω/KM | Ω/KM | Ω/KM | ||||||
0.5 | 7 | Â | Â | Â | Â | Â | 36 | 36.7 | Â |
0.75 | 7 | Â | Â | Â | Â | Â | 24.5 | 24.8 | Â |
1 | 7 | Â | Â | Â | Â | Â | 18.1 | 18.2 | Â |
1.5 | 7 | Â | 6 | Â | Â | Â | 12.1 | 12.2 | Â |
2.5 | 7 | Â | 6 | Â | Â | Â | 7.41 | 7.58 | Â |
4 | 7 | Â | 6 | Â | Â | Â | 4.61 | 4.7 | Â |
6 | 7 | Â | 6 | Â | Â | Â | 3.08 | 3.11 | Â |
10 | 7 | 7 | 6 | 6 | Â | Â | 1.83 | 1.84 | 3.08 |
16 | 7 | 7 | 6 | 6 | Â | Â | 1.15 | 1.16 | 1.91 |
25 | 7 | 7 | 6 | 6 | 6 | 6 | 0.727 | 0.734 | 1.2 |
35 | 7 | 7 | 6 | 6 | 6 | 6 | 0.524 | 0.529 | 0.868 |
50 | 19 | 19 | 6 | 6 | 6 | 6 | 0.387 | 0.391 | 0.641 |
70 | 19 | 19 | 12 | 12 | 12 | 12 | 0.268 | 0.27 | 0.443 |
95 | 19 | 19 | 15 | 15 | 15 | 15 | 0.193 | 0.195 | 0.32 |
120 | 37 | 37 | 18 | 15 | 18 | 15 | 0.153 | 0.154 | 0.253 |
150 | 37 | 37 | 18 | 15 | 18 | 15 | 0.124 | 0.126 | 0.206 |
185 | 37 | 37 | 30 | 30 | 30 | 30 | 0.0991 | 0.1 | 0.164 |
240 | 37 | 37 | 34 | 30 | 34 | 30 | 0.0754 | 0.0762 | 0.125 |
300 | 61 | 61 | 34 | 30 | 34 | 30 | 0.0601 | 0.0607 | 0.1 |
400 | 61 | 61 | 53 | 53 | 53 | 53 | 0.047 | 0.0475 | 0.0778 |
500 | 61 | 61 | 53 | 53 | 53 | 53 | 0.0368 | 0.0369 | 0.0605 |
630 | 91 | 91 | 53 | 53 | 53 | 53 | 0.0283 | 0.0286 | 0.0469 |
800 | 91 | 91 | 53 | 53 | Â | Â | 0.0221 | 0.0224 | 0.0367 |
1000 | 91 | 91 | 53 | 53 | Â | Â | 0.0176 | 0.0177 | 0.0291 |
Microphone Plug,Plug Angle,90 Degree Power Plug