Dry goods! Poor electrical parameter analysis and maintenance

To sum up, some practical personal maintenance experience of the maintenance staff at the frontline for many years, it may not look gorgeous, it does not necessarily contain a profound theoretical knowledge, but I found it really useful

Dry goods! Poor electrical parameter analysis and maintenance

Including but not limited to the following, the filter commonly used electrical parameters of poor analysis VS repair methods.

Poor electrical parameter analysis and maintenance
Defective item Influencing factors Solution
Bad insertion loss Design factors Design as much spare time as possible
Material reason Improve the performance of critical materials such as connectors and resonators, including plating, intermodulation, dimensions, roughness, and more
Debugging method Debug all indicators to optimum
plating Increase plating thickness
Instrument error Calibration to improve the accuracy of the instrument
Test factor

Improve the accuracy of the test bench itself;
Minimize the error of test methods as much as possible

Coupling plate Optimize microstrip line design; optimize coupling between the coupling plate and the main bar; reduce coupling.
Out of band Design reason Design as much spare time as possible
Low-pass reason

Whether the low-pass cover is tightened and re-tightened again;
Improve the dimensional accuracy of the low-pass groove, and strictly control the size within the required range;
Blow the heat shrink tube again.

Leakage of the cover

Raise the flatness and roughness of the cavity and the main cover plate;
Screw tightening torque increases;
Re-tighten the cover again.

Poor return loss Design reason Design as much spare time as possible
Material reason Improve the performance of critical materials such as connectors and resonators, including plating, intermodulation, dimensions, roughness, and more
Debugging method Debug all indicators to optimum
Instrument error Calibration to improve the accuracy of the instrument
Test factor

Improve the accuracy of the test bench itself;
Minimize the error of test methods as much as possible

Tap line

Ensure that the tap height;
Ensure the distance from the tap line to the cavity wall.

Lightning protection board

Improve the isolation of the lightning protection board;
Optimize microstrip line design.

Bad high and low temperatures Seal leakage Improve the airtightness of the chamber and prevent water ingress