Michael Abras was the chief scientist of Oculus. He also attended the F8 conference held recently and gave a keynote speech. The theme of this time in Abras is Augmented Reality. At this year's Facebook annual developer conference, augmented reality has become one of the hottest topics. In addition to Facebook’s launch of a camera-based platform, Abelashi’s speech gave us a glimpse into the future of glasses-based AR.
At the conference, Facebook's founder Mark Zuckerberg briefly talked about the exciting future of wearable AR hardware, and Michael Abrasch went deep into AR glasses. He believes that such products are "... On the road, and when it happens, they will become the most disruptive technology in the next 50 years."
Abelash believes that the impact of "the next wave of virtual information processing" (including VR and AR) may even exceed the personal computer revolution in the past 50 years. He predicts that we will wear fashionable glasses all day long, and this device can provide "AR, VR or in-between", allowing the virtual world and the real world to merge with each other and seamlessly interweave with us. In everyday life.
Abelashi pointed out that in the short term AR and VR will still develop along different hardware paths. Because of its lack of social acceptance, the "mixed reality that is always available everywhere, everywhere can be" will not be a strength of VR headlines; and perspective AR glasses is an acceptable virtual computing integration.
Abelush also proposed the concept of "Full AR", which he defined as "Seamless enhancement of hearing and vision; making you smarter and more capable; lightweight, comfortable, stylish, efficient, and socially acceptable Acceptance is enough to make it part of your daily life." This kind of hardware will become "you always on-line assistant, constantly perceive the environment around you, your situation and your history, constantly mix the real world with the virtual world to meet your needs and keep your network."
"Oculus Research is trying to study AR, but we are not enough." Aberash said that many key technologies are not yet available, but also outlined the challenges faced by R&D labs in the foreseeable future: All AR needs to be Major advances have been made in optics, display, audio, interaction, computer vision, AI, system design, UX, materials science, perceptual science and graphics. Abelashi believes that the interactive revolution is very important, and the final solution will be a "direct brain machine interface."
Abelash said: “Although everyone's attention is focused on AR today, it will take at least five years before we actually move into the 'Machine Computing Age' before the proliferation of glasses-based augmented reality begins. time."
Power Meter is a monitoring and testing instrument which determines the power consumption of a connected appliance and the cost of the electricity consumed.
Built-in 3.6V rechargeable Batteries ( . The purpose of the batteries is to store the total electricity and memory setting
Resetting
If an abnormal display appears or the buttons produce no response, the instrument must be reset. To do this,
press the RESET button.
Display Mode
Entire LCD can be displayed for about 1 minute and then it automatically gets into Model. To transfer from
one mode to the other, press the FUNCTION button.
Mode 1: Time/Watt/Cost Display Display duration(how long) this device connect to power source.LCD on first line shows 0:00 with first two figures mean minutes(2 figures will occur while occur at 10 min) and the rest shows seconds. After 60mins, it displays 0:00 again with first two numbers meas hour(2 figures will occur at 10hours)and the rest shows minutes. The rest can be done in the same manner which means after 24 hours, it will re-caculate. LCD on second line displays current power which ranges in 0.0W 〜 9999W. LCD on third line displays the current electricity costs which ranges in O.Ocost 〜 9999cost. It will keep on O.OOcost before setting rate without other figures.
Mode 2: Time/Cumulative electrical quantity Display Display duration(how long) this device connect to power source.
LCD on first line shows 0:00 with first two figures mean minutes(2 figures will occur while occur at 10 min) and the rest shows seconds. After 60mins, it displays 0:00 again with first two numbers meas hour(2 figures will occur at 10hours)and the rest shows minutes. The rest can be done in the same manner which
means after 24 hours, it will re-caculate. LCD on second line displays current cumulative electrical quantity which ranges in 0.000KWH 〜 9999KWH without other figures. LCD on third line displays"DAY"- "1 'Will be showed on numerical part(the other three figures will be showed at carry) which means it has cumulated electrical quantity for 24hours(one day). The rest can be done in the same manner untill the maximal cumulative time of 9999 days.
Mode 3: TimeA^bltage/Frequency Display LCD on first line displays the same as Mode 1 dones. LCD on second line displays current voltage supply (v) which ranges in 0.0V 〜 9999V .LCD on third line displays current frequency (HZ) which ranges in 0.0HZ 〜 9999Hz without other figures.
Mode 4: Time/Current/Power Factor Display LCD on first line displays the same as Mode 1 dones.LCD on second line displays load current which ranges in 0.0000A 〜 9999A. LCD on third line displays current power factor which ranges in 0.00PF 〜 LOOPF without other figures.
Mode 5:Time/Minimum Power Display LCD on first line displays the same as Mode 1 dones. LCD on
second line displays the minimum power which ranges in 0.0W 〜 9999W. LCD on third line displays character of "Lo" without other figures.
Mode 6: Time/Maximal Power Display LCD on first line displays the same as Mode 1 dones. LCD on second line displays the maximal power which ranges in 0.0W 〜 9999W. LCD on third line displays character of "Hi" without other figures.
Mode 7: Time/Price Display LCD on first line displays the same as Mode 1 dones. LCD on third line displays the cost which ranges in O.OOCOST/KWH 〜 99.99COST/KWH without other figures.
Overload Display: When the power socket connects the load over 3680W, LCD on second line displays the''OVERLOAD[ with booming noise to warn the users,( 1918928,selectable choice)
Supplemental informations:
1: Except [OVERLOAD[ interface, LCD on first line display time in repitition within 24hours.
2: LCD on first line, second line or third line described in this intruction take section according to two black lines on LCD screen. Here it added for clarified purpose.
3. Mode 7 will directly occur while press down button "cost".
4. [UP"&"Down" are in no function under un-setting mode.
Setting Mode
1. Electricity price setting
After keeping COST button pressed lasting more than 3 seconds(LCD on third line display system defaults price, eg O.OOCOST/KWH ),the rendered content begins moving up and down which means that the device
has entered the setting mode. After that, press FUNCTION for swithing , then press "UP"and "DOWN" button again to set value which ranges in OO.OOCOST/KWH 〜 99.99COST/KWH. After setting all above, press COST to return to Mode7 or it will automatically return to Mode7 without any pressing after setting with data storage.
LCD Display Power Meter Socket,Power Meter Plug Outlet,Electricity Usage Monitor Socket,LCD Energy Power Meter Socket,Digital LCD Power Meter Socket
NINGBO COWELL ELECTRONICS & TECHNOLOGY CO., LTD , https://www.cowellsockets.com