Reasons why the magnetic flap level gauge is installed at the flange interface

:
we know

Magnetic flap level gauge

The general installation methods are side-mounted and top-mounted, and the flanges of the mounting flanges are basically side-mounted, because the installation method of the top-loading causes the liquid in the main pipe to not enter the liquid, and the installation of the side-mounted device allows the liquid to enter. Go to the main pipe. Therefore, the installation of the top-loading magnetic flap level gauge has no effect.

So what is the reason for installing the valve at the flange interface when installing sideways?

In general,

Magnetic flap level gauge installation

As long as the specifications and precautions are met, there is basically no failure, unless

Magnetic flap level gauge selection

The error or the service life is up. In the event of a malfunction, the magnetic flap level gauge needs to be repaired or even replaced. At this time, if the valve is not installed at the flange joint, there is liquid in the main pipe, which cannot be disassembled for maintenance, because if the liquid is harmful to the human body, it is not acceptable.

If a valve is installed at the flange butt joint, when the fault needs to be disassembled or repaired or the main pipe is cleaned, the valve can be closed first, so that the liquid in the tank cannot flow out, which can solve the problem quickly and solve the problem. problem.

If the life of the magnetic flap level gauge is still very long, the use is no problem, but because the medium has a slight viscosity, after a period of use, it will affect the normal operation of the float, but safely give up the whole set of magnetic flaps. The level gauge is a pity, so you need to flush the main pipe, and closing the valve at this time will be very convenient to disassemble and worry about.

Zener Diodes

SMA means surface mount assembly. It is a new generation of electronic assembly technology, which compresses traditional electronic components into a device with a volume of only a few tenths.
Surface mounting is not a new concept, it is derived from earlier processes, such as flat mounting and mixed mounting.
For the assembly of electronic circuits, a point-to-point wiring method was initially adopted, and there was no substrate at all. The packaging of the first semiconductor device uses radial pins, which are inserted into the through holes of the monolithic circuit boards that have been used for the packaging of resistors and capacitors. Active components have been widely used in the past ten years.

Zener Diodes,Surface Mount Standard Rectifiers,Smd Bridge Rectifier,zener diodes manufacturers

Changzhou Changyuan Electronic Co., Ltd. , https://www.cydiode.com

Posted on